Ashkan Eliasy
Research · 20 Jun 2023
Inflation Tests Map Regional Stiffness of the Posterior Human Sclera
Inflation tests and inverse modeling of five donor sclerae matched displacements within 17.5 µm and showed stiffness falling toward the posterior pole.